Tronsole®
type
T
Load-bearing impact sound insulation element for connecting staircases to landings. The element transfers positive shear forces.


Advantages
Outstanding soundproofing
SSt III to VDI 4100 is achieved in a standard apartment building with all Tronsole® types − and also DEGA class A with certain product typesReliable and comparable sound attenuation values
Acoustic characteristic values of Schöck Tronsole® tested to DIN 7396; describes a method for measuring impact sound insulating elements for solid stairs and landings and enables comparison of decoupling elementsAcoustic characteristic values tested to DIN 7396
Evaluated impact sound pressure level difference ∆L*n,w ≥ 33 dB for load-bearing level V2 to ∆L*n,w ≥ 29 dB for load-bearing level V8
Evaluated impact sound pressure level difference ∆L*w, stair ≥ 28 dB for load-bearing level V2 to ∆L*w, stair ≥ 25 dB for load-bearing level V8Technical approval
Planning reliability with DIBt (German Institute of Building Technology) approval Z-15.7-310Certified fire protection
Supplied with fire resistance class R 90 as standard for reliable fire protection; use in rescue routes confirmed by fire performance assessmentsStraight joint profile
Enables straight joints and straightforward stripping of formwork at precast plant and on the construction siteIndividual dimensions
Tronsole® type T can either be cropped or made to measure; minimum lengths must be taken into consideration- Integrated nail strip
For easy attachment to formwork